PR116/21-R2

“Pressurization systems prevent the smoke getting into the protected space on all floors.”

 

“A further key consideration is the reliability of the smoke control systems.’ A pressurization will provide ambient air protection to escapees and the fire service personnel for the full duration of the fire service operation”.

                 

                 A Fan Assembly being lowered to the roof of a multi-storey building

 

It is commonly accepted that pressurization is the most suitable system of smoke control in tall buildings. Indeed, in the draft revision of BS9991 it states that a pressurization system should be used in all new single stair residential buildings greater than 18m in height.

 

However, the most common excuse for not adopting pressurization systems is that the systems, on a like for like performance criteria, are more costly and difficult to commission; this could not be more wrong.

 

Why Pressurization?

 

It has been common practice to design a depressurization smoke extract system based on a single fire on a single level. Recent experience of fires in multi-storey apartment buildings clearly demonstrates that fires in such buildings do not often respect this assumption.

 

A pressurization system on the other hand creates a positive pressure within the protected spaces, stopping smoke from entering the protected space in the first place, and are designed to cater for changes that will inevitably occur as occupants escape from the building and the fire service enter.

 

A key consideration in the design of a smoke control system must be the reliability of the smoke control systems’ performance and its sustainability, that is whether it can continue to provide protection to escapees and the fire service personnel for the full duration of the fire and fire service operations.

 

A depressurization extract fan is designed to function at an elevated temperature and heavy smoke mass for up to two hours, whereas a pressurization system handles cold air and will operate for however long the smoke control system is required.

                                Fire rated ductwork passing through the building

Modern Control Technology

 

Pressurization systems employing modern control technology are neither more expensive nor difficult to commission than depressurization systems when working to the same performance requirements. The most likely real reason for such excuses is that the designers find the calculations more complex than those required to design a depressurization system.

Using a simple door monitoring system to control the airflow of a pressurization system, as opposed to using pressure relief terminals or pressure sensors for controlling the airflow, makes significant savings in the time taken in commissioning.

                                             Fire rated dampers to each discharge

Using a laptop to set the airflow to each level of the building on the door monitoring sensors is often far more accurate and quicker at commissioning than trying to balance each level through dampers and/or pressure sensors.

 

It is worth adding that the reliability of the digital control system, and its response time to changing conditions, is far superior to the older form of system control. This is also the case for maintenance of the system.

 

Conclusion

 

With the more reliable and sustainable option of the pressurization system and its ability to control the level of smoke migration into the primary escape route of the stairwell providing a constant supply of fresh air for extended periods of time, this has to be the system of choice. But what is most important is the question that must be asked:

 

“what price a life?"

A Fan Assembly being lowered to the roof of a multi-storey building
Fire rated ductwork passing through the building
Fire rated dampers to each discharge
Advanced Smoke Group Logo

Advanced Smoke Group Ltd
46 Kenilworth Drive,
Oadby Industrial Estate,
Leicester
LE2 5LG

Contact details

+44 (0) 116 271 6861 

email logo
Hi-Protect logo, representing advanced high-rise smoke ventilation solutions
The institute of fire engineers affiliate organisation logo
Registered management systems accreditaion certificate
safe contractor approved logo
IFC-Certification-logo
bsi logo
Gold_RGB.png
Smas Logo July 2024.png
Home    Reports    Hi-Protect    About     Contact    Services    Projects

© 2024 Advanced Smoke Group Ltd.

All rights reserved

Advanced Smoke Group Limited is a company registered in England and Wales under the number 6709805. Registered office: 46 Kenilworth Drive, Oadby Industrial Estate, Leicester, LE2 5LG

bottom of page